Every one has a real cost, a real equipment list, a real number of weeks, and a specific list of deliverables.
Tap any project for the full build spec. The three that do 80% of the work are the O/W lotion, the scale-up study, and the INCI teardown.
🧴
Project 01
The O/W Body Lotion, Done Like a Product
Build a base emulsion lotion from a surfactant/emulsifier blend and a defined oil phase, then vary oil load and emulsifier level to map the window where the product is stable, spreadable, and manufacturable. Every variant gets a batch record, spec sheet, and cost line.
💵 Raw materials $38 (emulsifier blend $14, emollient oils $9, humectant + actives $6, preservative $5, salts/pH adjusters $4); instruments & consumables $27 (pH strips $8, mixing vessels + beakers $9, 0.1 g scale $10) — total $65
🧰 Home lab kit (scale, pH strips, beakers, immersion or overhead mixer), one shared oven for melting the oil phase.
⏱ 6–8 weeks
Why it screens well: Emulsion competence is the single most-tested skill in a cosmetic formulation interview. A candidate who can show why the HLB ratio changed droplet size — and what that did to viscosity, sensory, and preservative demand — reads as someone who has already done formulation work, not someone who followed a YouTube recipe.
Deliverables the page must show
- 1) Master formulation sheet with % w/w and function of every ingredient
- 2) Batch record with in-process checks (temp, mixing speed, addition rate, pH)
- 3) INCI breakdown table (ingredient → function → why chosen)
- 4) Droplet-size / microscopy image set across variants
- 5) Viscosity vs oil-load chart with replicates
- 6) Centrifuge or freeze–thaw stability results
- 7) Failure log (cracked emulsion, phase separation, graininess) with diagnosis
- 8) Sensory panel scores (n = 8) on spreadability, greasiness, after-feel
- 9) Cost-per-100 g and cost-per-kg projection
- 10) One-page spec sheet with proposed release criteria
Techniques & instruments
- HLB balance
- Bancroft (water/oil ratio) considerations; phase inversion temperature (PIT) method; optical microscopy (drops on a slide)
- Brookfield-style spindle viscometer; centrifugation as a accelerated separation screen; pH (strip and probe); freeze–thaw cycling; sensory panel with a defined scoring sheet
C1 — Emulsion science (O/W)source
🧈
Project 02
The Anhydrous Balm & W/O Balm
Formulate a beeswax/candelilla butter base as a solid W/O anhydrous balm, then convert one variant into an emulsified balm with water added, and compare melt point, spreadability, water uptake and microbial risk. The anhydrous-vs-emulsified comparison is the intellectual core.
💵 Waxes & butters $16, carrier oils $9, actives $8, packaging (tins, pots) $7; instruments $20 (scale, thermometer, metal spatulas, moulds) — total $60
🧰 Home lab kit plus heat source (hot plate / rice cooker + thermometer) for melting; borrowed oven for holds.
⏱ 5–7 weeks
Why it screens well: It proves she understands why waterless formats are chosen (no preservative challenge, no emulsion, shipping weight, hot-fill) — which is exactly the argument a waterless-position brand or a sustainability-focused recruiter will make. It also shows product-family thinking: one platform, two formats.
Deliverables the page must show
- 1) Formulation sheet with w/w % and function per ingredient
- 2) Batch record with melt/hold/pour temperatures and cooling curve
- 3) DSC or simple melt-point profile (softening point vs formulation)
- 4) Water-uptake test (Anhydrous vs emulsified, mass change over 24 h)
- 5) Accelerated stability (40 °C, 1 week) with photos
- 6) Microbial risk rationale for the anhydrous claim
- 7) Spreadability scoring (n = 8) and consumer texture words
- 8) Cost-per-unit and cost-per-100 g
- 9) Packaging-compatibility note for each tin/jar material
Techniques & instruments
- Melt-point depression via DSC or capillary method; hot-fill and pour-temperature window; water activity (aw) reasoning; hardness/penetration as a proxy for spreadability; bench-top cooling-rate curve; organoleptic panel; simple aw estimation from formulation
C2 — Anhydrous / W-O systemssource
🫧
Project 03
Micellar Cleansing Water: A Surfactant System Study
Design a sulfate-free micellar cleansing water from a surfactant blend (e.g. a mild anionic + a nonionic solubiliser), then vary the surfactant-to-oil ratio to map the line between "cleans without stripping" and "too weak to emulsify sebum." Measure pH, clarity, and emulsification power on a sebum analogue.
💵 Surfactants (a mild anionic + nonionic + solubiliser) $16, actives (glycerin, panthenol) $7, water, packaging and consumables $9; instruments $18 (pH strips, 50 mL beakers, pipettes, 10 mL syringes) — total $50
🧰 Home lab kit; inversion test tubes; optional borrowed spectrometer for turbidity.
⏱ 4–6 weeks
Why it screens well: Surfactant selection and HLB/mildness reasoning is the #1 whiteboarding question in cosmetic R&D interviews (source: Chemistry Job Insight formulation interview guide). Showing a ratio study with an endpoint is the difference from "I mixed surfactants together."
Deliverables the page must show
- 1) Surfactant screening table (HLB, charge, % active, pH of 1% solution, cost)
- 2) Formulation grid with % surfactant vs % oil
- 3) Emulsification-power endpoint (number of inversions or time to re-emulsify after 10 flips)
- 4) Turbidity/clarity photos across the grid
- 5) pH and a foam/cleanliness comparison
- 6) Failure log (clouding at high oil, solubiliser failure at low surfactant)
- 7) Skin-tolerance reasoning (surfactant selection criteria and what was not tested)
- 8) Cost per 200 mL
- 9) A "what I would test next" section naming a real protocol
Techniques & instruments
- HLB selection
- Krafft point / cloud point reasoning; solubilisation capacity; inversion-test emulsification power; foam height (simple cylinder test); turbidity/clarity by eye with a printed reference card; pH at 25 °C
C3 — Surfactant & micelle sciencesource
🧫
Project 04
Pickering Emulsion: Stabilising with Particles Instead of Surfactant
Build a particle-stabilised emulsion using a cosmetic-compatible solid (e.g. silica, kaolin, or hydroxyapatite) instead of a polymeric emulsifier, and compare droplet stability, creaming, and interfacial behaviour against a surfactant-stabilised control.
💵 Solids (silica, kaolin) $12, oil phase $9, a small polymeric emulsifier for the control $8, other consumables $6; optics consumables $20 (slides, coverslips, pipettes, a smartphone microscope adapter) — total $55
🧰 Borrowed optical microscope (UCI or high-school lab); home lab kit for mixing; centrifuge access via a cooperating lab if available.
⏱ 7–9 weeks
Why it screens well: It is the most obviously "engineer" project on this list, and it is rare at the undergraduate level. Hiring managers read it as: she can read a colloid-science paper, reproduce a published concept, and characterise it. It also maps directly onto a growing ingredient category (solid-particle stabilisation) with real commercial relevance.
Deliverables the page must show
- 1) Concept sheet with the published method you replicated (full citation)
- 2) Particle characterisation (size, morphology from micrographs)
- 3) Micrograph series with scale bar and droplet-size distribution
- 4) Droplet-size distribution vs particle concentration
- 5) Centrifuge and freeze–thaw stability vs surfactant control
- 6) Creaming index vs time
- 7) Failure log (agglomeration, creaming anyway, visual grittiness)
- 8) Sensory/appearance limitation analysis (grittiness = why industry uses polymeric emulsifiers)
- 9) Cost and a "would you ship this?" memo
Techniques & instruments
- Optical microscopy with scale bar; contact-angle reasoning for particle wetting
- Pickering stabilisation criterion (particle vs droplet size); creaming index; centrifugation; emulsion phase inversion considerations; image analysis (ImageJ or Figma measurement) for droplet sizing; basic zeta-potential reasoning stated as limitation
C4 — Colloid & Pickering stabilisationsource
💊
Project 05
Encapsulated Active: Liposome vs Spray-Dried Powder
Encapsulate one cosmetic active (e.g. niacinamide, salicylic acid, or bakuchiol) two ways — a simple phospholipid liposome built at the bench, and a spray-dried powder on a carrier (e.g. trehalose or cyclodextrin) — then compare encapsulation efficiency, payload retention, and release behaviour under simulated skin conditions.
💵 Phospholipid + active $34, carrier/excipients (trehalose, cyclodextrin) $10; consumables & columns $16 (dialysis tubing, filters, syringe filters, UV cuvettes) — total $60
🧰 Borrowed UV-Vis spectrophotometer (UCI lab, ideally with a supervising faculty member); home lab kit for mixing; access to a bench spray dryer only via a partnering lab, otherwise use a shaker/evaporation-crystallisation route and say so.
⏱ 10–14 weeks
Why it screens well: Delivery systems are where cosmetic R&D is heading, and where a ChemE is more competitive than a cosmetic-science major. Two-method comparison with a measured efficiency is a genuine engineering result, not a recipe.
Deliverables the page must show
- 1) Encapsulation methods sheet with both routes and full citations
- 2) Calibration curve (absorbance vs concentration) with R²
- 3) Encapsulation efficiency and loading capacity for both methods
- 4) Particle-size distribution for the liposome (DLS or microscopy) and the powder (laser diffraction/ sieving if available)
- 5) Release curves in simulated conditions (with the assay caveat stated)
- 6) Photostability or oxidation comparison with and without encapsulation
- 7) Failure log (phase separation, payload loss, low encapsulation in the bench-scale liposome)
- 8) Raw-data files and the analysis script/notebook
- 9) Honest limitation section: bench liposomes are not lipid nanoparticles
Techniques & instruments
- UV-Vis spectrophotometric assay; dialysis or centrifugation separation of free vs encapsulated payload; dynamic light scattering; encapsulation efficiency (mass-balance) calculation; release kinetics with sink conditions; spray drying or evaporative crystallisation; basic oxidative-stability (iodine or peroxide value on an oil carrier)
C5 — Encapsulation & delivery systemssource
🧴
Project 06
Waterless Powder-to-Liquid Cleanser / Waterless Serum
Build a powder cleanser or waterless serum format (e.g. kaolin or konjac-based, or a surfactant powder) that reconstitutes into a usable product with a controlled amount of water, and compare it against the same actives in a conventional water-based format for cleaning performance, user experience, and total packaging/water footprint.
💵 Powders (kaolin, konjac, or surfactant powder) $18, binder/structuring agent $12, actives $7, packaging $8; instruments $15 (sieve, scale, humidity-sensitive container) — total $60
🧰 Home lab kit; borrowed muffin mixer or food processor for blending (or a pestle and mortar, stated).
⏱ 6–8 weeks
Why it screens well: Waterless is the fastest-moving format trend in beauty, and the argument for it is quantitative. Showing that a powder delivers equal performance with less water and less packaging — and being honest about where it is worse — signals commercial maturity. It also fits a green-chemistry recruiter's screen.
Deliverables the page must show
- 1) Format rationale (water removal: efficacy, preservation, shipping weight, packaging)
- 2) Formulation sheet with reconstitution ratio
- 3) Reconstitution protocol and time-to-mix curve
- 4) Performance comparison vs water-based control on a sebum-analogue swatch (cleaning removal %)
- 5) Sensory panel on powder feel, lather, rinse-off residue
- 6) Water saved per 100 uses (calculated) and packaging-mass comparison
- 7) Failure log (clumping, poor reconstitution, actives inactive in dry matrix)
- 8) Shelf-life argument and a first-pass stability check
- 9) Cost per use vs the conventional format
Techniques & instruments
- Water activity and its role in dry-format stability; reconstitution/solubility screening; particle size by sieving; sebum-analogue removal assay on artificial skin (Vitrofilm-type substrate); lather/foam assessment; mass-balance water and packaging calculation; sensory panel with a defined protocol
C6 — Waterless & powder formatssource
🌍
Project 07
Green-Chemistry Metrics of a Real Formulation: PMI and E-Factor
Take one finished formulation you have already made and compute Process Mass Intensity and E-Factor for its bench manufacture, then propose a redesign (e.g. concentrate, solvent-free hot-melt, or waterless) and quantify the improvement in both PMI and waste per unit.
💵 Materials for the baseline and one redesigned formulation $45; consumables (weighing vessels, labels) $10; analysis in Excel $0 — total $55
🧰 Home lab kit only (scale is the instrument that matters).
⏱ 4–5 weeks
Why it screens well: PMI and E-Factor are standard, citable green-chemistry metrics with published methodology. A student who computes them for a cosmetic formulation — where most examples are from pharma synthesis — demonstrates metric literacy plus genuine reformulation thinking. It is also the easiest high-signal project in this list because it needs almost no new equipment.
Deliverables the page must show
- 1) Formulation sheet with every input massed and classed (raw material vs water vs solvent)
- 2) PMI calculation for the baseline, step by step, in a spreadsheet with visible formulas
- 3) E-factor (kg waste per kg product) with the waste stream identified (aqueous rinse, discarded batch, off-spec)
- 4) Water-energy intensity per unit
- 5) One redesign with recomputed PMI/E-factor and a % improvement bar chart
- 6) Green chemistry principle mapping (waste prevention, atom economy, less hazardous synthesis, energy efficiency) with the unmet principles named
- 7) Limitations section (bench scale, no solvent recovery, energy estimate from published values)
- 8) The full workbook as a downloadable file
Techniques & instruments
- Process Mass Intensity (step and cumulative)
- E-factor; water intensity; energy intensity; mass balance accounting; green chemistry principle mapping; simple sensitivity analysis (how much does the metric change if the yield drops?)
C7 — Green chemistry & process metricssource
🌀
Project 08
Scale-Up & Mixing Science of One Formula
Take a single bench formula (ideally the Project 1 lotion) and reason it from 100 g to 1 kg to a 100 kg pilot, using power/volume scaling, Reynolds number for the impeller, tip speed, shear rate, and cooling duty. Include a failure-mode memo for what breaks at each step.
💵 Materials to make the 1 kg batch and run the scaling experiments $30; instruments (pH probe, thermocouple, stopwatch, impeller/borosilicate vessel or a borrowed 5 L pot) $35; simulation software (Excel or an open-source flowsheet tool) $0 — total $65
🧰 Borrowed or purchased 5 L mixing vessel + a variable-speed mixer; home lab kit for the small batches; spreadsheet.
⏱ 8–10 weeks
Why it screens well: Process engineering is where her ChemE degree literally pays off, and it is the rarest thing an undergraduate can show a contract manufacturer or CMO. A CMO hiring manager wants to know she can think in batches, not tubes. This is the single highest-leverage non-bench project here.
Deliverables the page must show
- 1) Process flow diagram (P&ID) from raw material receiving to filling
- 2) Equipment list with sizing justification (impeller type, tip speed, rpm, HP)
- 3) Reynolds number calculation for the mixing regime at each scale with the assumption list
- 4) Mixing-time and blend-time comparison (colour-tracer method) across scales
- 5) Cooling duty / heat balance for the water and oil phases
- 6) Mass-energy-cost model spreadsheet with formulas visible
- 7) Failure-mode memo (shear-sensitive actives, cooling-rate crystallisation, pH drift, scale-up of a preservative, powder agglomeration) with mitigations
- 8) Cost of goods at 3 scales with a chart showing where margin compresses
- 9) A P&ID image plus a downloadable workbook
Techniques & instruments
- Reynolds number and power number (P/N vs Re); tip speed and shear rate; blend-time curve (tracer method); heat balance and cooling duty; dimensionless scale-up criteria (constant tip speed, constant P/V, equal blend time); mass-energy balance; solids suspension / yield-stress reasoning for powders; cost-of-goods scaling
C8 — Scale-up & mixing sciencesource
🧪
Project 09
Stability & Compatibility Study: Accelerated + Real-Time
Run a designed stability study on your own formulations: freeze–thaw, 40 °C/50 °C accelerated, and real-time ambient, with pH, viscosity, appearance, odour, and microbial checks over time. Add a packaging-compatibility arm across three container materials.
💵 Materials for a 3-variant stability set $30; packaging (jars, tubes, airless-less containers, 3 materials) $25; instruments (pH, viscosity, incubator access free via UCI or a home oven with a thermometer) $20 — total $75
🧰 Home lab kit plus a temperature-controlled space (UCI lab, borrowed oven, or a controlled box); borrowed viscometer.
⏱ 8–12 weeks of elapsed time (6 weeks of hands-on work)
Why it screens well: Stability is where formula cost gets decided in industry, and it is the topic students almost never document. A stability plot with a stated protocol and an interpretation ("pH drift of 0.3 over 6 weeks suggests ester hydrolysis in phase B") is a very high-trust artifact for very little money.
Deliverables the page must show
- 1) Stability protocol (test types, timepoints, sample sizes, storage conditions, acceptance criteria)
- 2) Time-series charts for pH, viscosity, appearance score, odour
- 3) Photo series at each timepoint on a fixed background with a scale reference
- 4) Freeze–thaw and heat-cycle results
- 5) Centrifuge results tied to the stability data
- 6) Packaging-interaction summary across the three container materials
- 7) Failure log with the root cause you believe for each out-of-spec event
- 8) Proposed shelf-life and storage recommendation, with the caveat that real-time data is still incomplete
- 9) A one-page shelf-life memo
Techniques & instruments
- Accelerated and real-time stability protocol design; freeze–thaw cycling; centrifugation as a separation screen; pH drift and its mechanistic causes (ester hydrolysis, oxidation of unsaturated oils); viscosity over time; light stability (window vs closed cabinet); basic microbiological screen (ATCC streaks or a preservative-efficacy test on a defined medium)
C9 — Stability & shelf-lifesource
🛡
Project 10
Preservative Hurdle System Study ️
Study the preservative hurdle: a water-containing formula in which you lower preservative concentration by combining multiple hurdles (pH, low aw, ethanol, chelator, packaging). Map the region of the hurdle map where microbial growth is prevented, and verify with a real preservative-efficacy test.
💵 Preservative systems (phenoxyethanol blend, organic acid, chelator, ethanol) $28; media and challenge organisms/ingredients $22; consumables (swabs, dilution tubes, incubation media) $15; incubator access free via UCI lab — total $65
🧰 UCI microbiology lab access (working with a supervisor) or a borrowed incubator; home lab kit for formula preparation; sterile technique space.
⏱ 8–10 weeks
Why it screens well: "Does it stay safe?" is the first question about any new cosmetic formula, and hurdle systems are how modern brands reduce preservative load (and how waterless products avoid the problem entirely). Running a PET (preservative efficacy test) or a modified USP/ISO-style screen on your own formula is a strong, verifiable artifact.
Deliverables the page must show
- 1) Hurdle-factor matrix (pH, aw, ethanol, chelator, preservative, packaging) with the target region marked
- 2) Formulation set across the matrix
- 3) Preservative efficacy / microbial challenge results with colony counts
- 4) Time-to-failure per formulation
- 5) Explanation of why each hurdle contributes (membrane, enzyme, metabolic interference)
- 6) Comparison against the preservative level a conventional formula would need
- 7) Failure log (which hurdles failed alone)
- 8) Package-closure interaction note
- 9) A clear statement of what a student lab cannot certify (no validated PET claim without a registered lab)
Techniques & instruments
- USP <51> / ISO 11930 style challenge-test framing; preservative efficacy (zone-of-inhibition and log-reduction); water activity measurement or calculation; pH effect on preservative activity; chelation (EDTA) effect; ethanol content as a hurdle; aseptic technique; colony counting
C10 — Preservative & hurdle systemssource
🏷
Project 11
INCI & Claims Teardown of a Shelf Product ️
Take a real product from a shelf (a bestseller, a "clean beauty" claim product, and an SPF product), decode every INCI entry by function, check the claims against the label and the evidence, and run a California Safe Cosmetics Act + MoCRA labeling screen. End with a one-page "what I would reformulate or relabel" memo.
💵 Shelf products to analyse (3–4) $40; tools $15 (magnifier, ruler for label reading, printed templates, colour card) — total $55
🧰 No lab equipment; a desk, a spreadsheet, and public regulatory databases.
⏱ 4–6 weeks
Why it screens well: Regulatory literacy is the most under-supplied skill in this industry and the easiest to demonstrate publicly without a lab. A teardown that cites the actual regulation and proposes a specific fix is a portfolio page that a recruiter can read in three minutes and a hiring manager can probe in an interview.
Deliverables the page must show
- 1) INCI decoder table (ingredient → function → concentration band → concern/regulatory status)
- 2) Claim-vs-evidence gap analysis with the evidence actually cited by the brand (or "none found")
- 3) MoCRA compliance screen — responsible person, product listing, facility registration, adverse-event reporting, domestic address, warning statements, cosmetic product listing
- 4) California Safe Cosmetics Act screen (Prop 65-style chemical reporting relevance)
- 5) One-page "what I'd fix" memo (reformulation or repackaging, with the trade-off stated)
- 6) A comparison table across the three products showing formulation architecture differences
- 7) A claim language rewrite of one marketing claim into a legally supportable claim
- 8) A glossary appendix
- 9) A short written summary (400 words) suitable for a Substack or LinkedIn post
Techniques & instruments
- INCI decoding and functional classification; ingredient-order interpretation
- FDA MoCRA and Cosmetics Labeling regulation reading (21 USC 364e, CFR Part 740)
- California Safe Cosmetics Act (SB 484) screening
- EU Cosmetic Regulation comparison (optional); allergen-fragrance screening; claim substantiation review; "natural ≠ safe" analysis with citations
C11 — Regulatory, INCI & claimssource
📊
Project 12
Instrumented Sensory & Consumer Panel
Run a small but instrumented consumer panel on your own formulas: a defined panel (n = 12–20, screened for skin type), a fixed questionnaire on texture and after-feel, paired with instrumented proxies (spreadability force, gloss, film weight) and a naive-vs-trained split.
💵 Panel compensation (gift cards) $30, formulations for the test $25, panel logistics/room & consumables $10 — total $65
🧰 Home lab kit for preparing blinded coded samples; borrowed lightbox or a fixed lighting setup; a camera on a tripod; a simple spreadability rig (a horizontal surface + a fixed mass).
⏱ 6–8 weeks
Why it screens well: Sensory evaluation is a real, paid discipline in cosmetics, and almost no student has ever run a controlled panel. Showing that she can define attributes, recruit a panel, run blinded, and analyse the result — with the explicit statement that she is not a trained sensory panelist — reads as professional. It also demonstrates that she can design evidence for a marketing claim.
Deliverables the page must show
- 1) Panel plan — recruitment criteria, n, blinding scheme, questionnaire, and ethics/safety note (no unpatched actives on participants)
- 2) Attribute definitions and the scales used
- 3) Raw scores published (not just the mean)
- 4) Results chart with spread and the naive-vs-trained comparison
- 5) Instrumented texture proxy results (spread diameter under fixed mass, gloss) correlated against the panel's perception
- 6) Photographs of the coded, standardised setup
- 7) What the panel could not tell you (limits of n, no trained panel)
- 8) A one-page "what a trained panel would do differently"
- 9) Anonymised raw data file
Techniques & instruments
- Blinded sensory evaluation; attribute development and descriptor scaling; panel recruitment and screening; paired comparison and preference mapping; naive vs trained panel analysis; texture measurement by simple instrumental proxy (spread area under a fixed mass); gloss measurement by photography under fixed lighting; simple statistics (means, spread, and a stated significance threshold)
C12 — Sensory & consumer perceptionsource
🌱
Project 13
Bio-Based vs Synthetic Active Comparison
Compare a bio-derived and a synthetic-sourced version of the same functional active (e.g. squalane: plant-based vs fermentation-derived vs petrochemical; or a fermentation-derived actives set), on functional performance, oxidative stability, cost, and supply origin.
💵 Commercial actives for comparison (3–4 grades of squalane or equivalent) $55; instruments $20 (pH, UV-Vis or peroxide/iodine value test on the oils, balance) — total $75
🧰 Home lab kit plus a borrowed UV-Vis (for peroxide value or absorbance) and a fume hood for iodination; product datasheets as the primary source for specification data.
⏱ 6–9 weeks
Why it screens well: This is where San Diego's biotech ingredient scene and the mainstream beauty industry now collide — San Diego's Debut Biotech, for example, is explicitly building cell-free biomanufactured cosmetic actives. Comparing actives on data rather than marketing is the exact posture an R&D employer wants, and it directly teaches the ingredient-sourcing vocabulary of the green-chemistry arc.
Deliverables the page must show
- 1) Source and supply-chain map for each active grade (origin, process route, supplier, published spec)
- 2) Comparative spec table (purity, appearance, odour, peroxide value, colour, spreadability) measured by you where possible
- 3) Oxidative stability comparison (iodine value over 4 weeks at 40 °C)
- 4) Performance test in a finished formula (e.g. emulsion appearance, spreadability, film feel)
- 5) Cost-per-use comparison at two formula loadings
- 6) A sustainability comparison that names its method (biogenic vs petrochemical content) rather than making a vibe claim
- 7) Failure log (spec variance between batches, odour differences, odour differences driving formula changes)
- 8) A sourcing recommendation memo with the trade-offs
- 9) An explicit "marketing vs measured" table
Techniques & instruments
- Peroxide value / iodine value titration; oxidative stability (40 °C, accelerated)
- UV-Vis absorbance for colour and spec comparison; supplier datasheet comparison and COA reading; emulsion performance (Project 1 framework); cost-per-use modelling; carbon/biogenic-content reasoning at a stated level of evidence
C13 — Bio-based & biotech activessource
📦
Project 14
Packaging–Product Interaction Study
Test your own formula against three packaging systems (e.g. HDPE jar, PET bottle, aluminium tube, plus one airless-like option) for compatibility, light protection, oxygen ingress, and consumer-perceived issues — including a simple leachables screen on the oil phase.
💵 Packaging (three to four formats, small quantities) $45; formulations $25; instruments and consumables $15 (leachables filters, UV-Vis, weight for permeation) — total $85
🧰 Home lab kit; borrowed UV-Vis and a balance for permeation/mass-loss tests; a controlled light exposure setup (window + fixed geometry).
⏱ 6–8 weeks
Why it screens well: Packaging is where a formula gets killed in industry, and packaging–product interaction sits squarely in chemical engineering (materials, permeation, mass transfer). Doing it on your own formula rather than on a brand's product shows you understand that the package is part of the formula.
Deliverables the page must show
- 1) Packaging selection matrix (material, wall, closure, expected compatibility risks)
- 2) Compatibility test plan and results per package
- 3) Light-protection comparison (absorbance/colour change under fixed UV exposure)
- 4) Permeation or mass-loss data with the mechanism stated (sorption/diffusion)
- 5) Simple leachables screen with method and detection limit stated
- 6) Photos of every package/condition/timepoint
- 7) Failure log (yellowing, odour pickup, lid leakage, delamination)
- 8) Recommendation memo with a packaging choice and a fill-line/closure note
- 9) A caveat that student packaging screening is not a regulatory extractables assessment
Techniques & instruments
- Light stability (fixed-geometry UV exposure); permeation / mass-loss (gravimetric); simple organic-extract screening with a stated solvent and detection limit; sorption reasoning; closure/seal compatibility; visual and odour assessment; drop/handling check; dimensional and labelling compliance check against 21 CFR 701 (naturally a basic labelling review)
C14 — Packaging–product interactionsource
💰
Project 15
Cost of Goods Model for a Formulation
Build a transparent cost-of-goods model for one real formula: raw material costs at three volume tiers, labour and overhead allocation, packaging, freight, and gross margin at three retail price points — then show which single ingredient dominates cost and what reformulation could change it.
💵 $0 in materials (reuse existing formulation data); consumables $15 (printing, a published price list); software $0 (Excel or Google Sheets) — total $15
🧰 None beyond a laptop and a spreadsheet.
⏱ 3–4 weeks
Why it screens well: Almost nobody at the undergraduate level can talk about the business of a formula, yet every indie brand founder and every product lead makes decisions on exactly this model. It is the cheapest, fastest project on the list (essentially spreadsheet work) and it signals commercial judgement, which is what gets a ChemE hired as a product developer rather than a lab technician.
Deliverables the page must show
- 1) Bill of materials with supplier and price per kg (screenshot or link, dated)
- 2) COGS model at 3 volumes and 3 retail prices, with formulas visible in the workbook
- 3) Waterfall chart showing cost drivers
- 4) Margin sensitivity to the top-3 cost drivers
- 5) A reformulation proposal with a cost/performance trade-off (e.g. lower-cost emulsifier → stability risk)
- 6) A packaging-inclusive cost per unit
- 7) A "what a real brand would do" memo — what to cut, what to protect, and why
- 8) A note on which prices were quoted vs estimated
Techniques & instruments
- Bill of materials and cost roll-up; volume-tier pricing; overhead and labour allocation; margin arithmetic; sensitivity analysis (tornado chart); packaging and freight in the unit cost; make-versus-buy reasoning (vs a CMO's quote); quote-request emails to real suppliers
C15 — Cost of goods & process economicssource
🏁
Project 16
Capstone-Scale Flagship Product System
One finished product platform with three variants (e.g. a leave-on lotion, a rinse-off cleanser, and a waterless serum sharing actives), each with a full formulation, an INCI and regulatory file, a stability dataset, a cost model, and one instrumented study — presented as a product line a brand could launch, not a lab exercise.
💵 Materials across three products $90; one outsourced testing block (stability or a claim panel at a testing lab) $150; packaging $30; printing/presentation $25 — total $295
🧰 Home lab kit plus borrowed instruments (viscometer, microscope, UV-Vis, incubator) from UCI or a partner lab; one paid external test block.
⏱ 16–20 weeks (can be run as a semester or a summer)
Why it screens well: This is the artifact that lets an interviewer imagine her in their lab on day one. It shows range, judgement, cross-functional thinking (regulatory + cost + consumer), and the discipline of a complete package. It is also the strongest possible answer to "tell me about a project you led."
Deliverables the page must show
- 1) Product-line concept with the consumer problem and target claim for each product
- 2) Full formulation set (3 products) with INCI breakdowns
- 3) A specification sheet per product with proposed release criteria
- 4) Stability dataset for the lead product
- 5) Cost model across the three products
- 6) One instrumented study per product (rheology, sensory, preservative)
- 7) Regulatory screen of the line
- 8) A 5-minute walkthrough video or slide deck with narration
- 9) A "post-mortem" section: what you would change in version 2 and why
- 10) A downloadable one-page line summary that a recruiter can print
Techniques & instruments
- Full formulation and process design; specification setting; release-criteria definition; stability protocol execution; cost modelling; regulatory screening; sensory evaluation; scale-up reasoning applied to a product line; project management across three workstreams; technical writing for a non-specialist reader
C16 — Full-formulation integration (capstone)source